FLYTEK GPU – 400Hz GPU | 45 KVA – 180 KVA

FlyTek AC GPU

FlyTek GPUs (Ground Power Units) contain power ratings from 45KVA to 180kVA making this product line perfect for any commercial, industrial or military application involving a variety of aircrafts. Through innovative research and development, FlyTek GPUs are efficient, easy to operate and maintain. They use double conversion technology with an integrated inverter output transformer to ensure galvanic isolation of the load. Dependent upon rating, these units are available in mobile, towable, and fixed configurations. In addition, FlyTek offers 28VDC/AC combination units.

Specifications

Input

  • 3 phase 460V / 480V AC | ± 10%
  • 50/60Hz | ± 10%
  • Input current harmonics | <2% @ Full Load

Output

  • 3 phase 200V AC -400Hz | ± 1%
  • Overall Efficiency | 90% – 95%
  • Max. Crest Factor | 1.4:4
  • 45 kva (208/230v or 460/480v input)
  • 90 kva (208/230v or 460/480v input)
  • 180 kva | Dual 90 kva (208/230v or 460/480v input)

Rectifier

  • 4 Quadrant Operation
  • AC Voltage Range | -25% + 10%
  • Efficiency | 95%-97%
  • Input Frequency Deviation | 10%
  • Overload Capacity | 120% Continuous
  • Inrush Current | None
  • Overall current limit | 150%

Inverter

  • Static Regulation 0 – 100% load | ± 1%
  • Dynamic regulation 100% | 10%, recovering to 1% within 2ms
  • Total harmonic distortion | Better than 2% (Linear Load)
  • Electronic Limit Overload | 120%@600s; 150%@60s; 200%@5s
  • Overload Capacity (IGBTs) | 150% Continuous
  • Frequency stability | ±0.01 Crystal Controlled
  • Load power factor | 0-1
  • Efficiency | 95% 98%
  • Short circuit proof by electric current limiting and shutdown

Environmental Conditions

  • Coolant temperature (max) | Forced air up to 40°C
  • Ambient temperature (min/max) | -40°C to 40°C
  • Relative humidity (min/max) | 0% to 90% without condensation
  • Pollution degree | 2
  • OVC (Overvoltage Category) | 3
  • Altitude | Up to 2000m

Technical Drawing